    DZ47S-125 Miniature Circuit Breaker (known as shunt trip MCB, 100 amp Circuit Breaker shunt trip). The shunt trip MCBis suitable for the control line of AC 50Hz or 60Hz, rated voltage 230V/400V, rated current of 125A and below, remote control and automatic signal breaking control for the line, is mainly used for over-load and short-circuit protection in circuits. And infrequent transfer between circuits in normal condition. Currently the shunt trip MCB is widely used in single-phase/ three-phase intelligent prepaid energy meter (such as IC card) to achieve the on-off of control lines. The series of products have high breaking capacity, small size, light weight, parts versatility, beautiful appearance, etc., it is mounted on the rail and easy to use.
    DZ47S-125 shunt trip MCB comply with standards of GB10963.1, IEC60898-1.

    Model and meaning

    Technical parameters

    ■ Rated current: 63,80,100,125A
    ■ Poles: 1P + N / 3P + N
    ■ Rated working voltage: 1P + N 230V; 3P + N 400V
    ■ Frequency: 50Hz
    ■ Operating voltage range: (65% ~ 120%) Un
    ■ Breaking capacity: 230V (1P + N), 400V (3P + N);
    ■ Delay action time (intelligent shunt tripping time): 0.5s ~ 2s
    ■ Reset time: <30s
    ■ Mechanical life: 10,000 times
    ■ Electrical life: 2000 times
    ■ Current Limit Level: 3
    ■ Impulse withstand voltage: 6kV
    ■ Dielectric strength: can withstand 2500V, Power-Frequency Withstand Voltage lasted 1min
    ■ Protection class: Ip20
    ■ Ambient temperature: -30 ℃ ~ 60 ℃
    ■ Resistance to heat and humidity: Class 2 (relative humidity 95% at 55 ° C)
    ■ Wiring: terminal wiring area, for 50mm ² and below of the wire
      □ Tunnel-type terminal blocks, up and down locking clamp, easy to install. Terminal tightening torque is 3.5N · m.
    ■ Signal connects wire
      □ The signal line is located at the bottom of the circuit breaker
      □ Cross-sectional area of independent signal is 0.5mm ², length is 1m, length of the signal line can be customized according to customer demand
    ■ Standards: GB10963.1
    ■ Certification: CCC
    ■ Tripping characteristics: Type C curve
      □ To protect the conventional load and distribution cables
      □ Tripping characteristics: instantaneous trip range (5 ~ 10)In

    Normal operating conditions and installation conditions

    ■ The ambient air temperature is -5 ℃ ~ +40 ℃, and the average temperature within 24h does not exceed +35 ℃.
    ■ Altitude of the installation site should not exceed 2000m.
    ■ Atmospheric relative humidity at ambient air temperature is + 40℃ for not more than 50%, in the low temperature can have higher relative humidity. Consider the temperature changes in product on the surface of the gel and take special measures.
    ■ Pollution Degree: Grade 2.
    ■ The inclination of the mounting plane to the vertical plane shall not exceed ± 5 °.
    ■ Installation conditions: Installed in a place without significant impact, vibration, non-hazardous (explosive) medium. And in no explosion danger media, and medium without enough to corrode the metal and destruction of gas and electric insulation dust place, in no rain and snow hit place.
    ■ Installation: mounted on the TH35-7.5 rail, Installation is vertical installation generally, handle-up means power-on.
    ■ Installation category: Ⅲ.

    Overcurrent protection characteristic

    Rated current
    In(A)
    Initial state Test current Limited time Prosrective result Remark
    In=63A In>63A
    63
    80
    100
    Cold 0.5In t≤1h t≤2h Non tripping
    Then after the
    last test
    1.30In t<1h t<2h Tripping The current rise immidiately
    to a fixed value
    Cold 8In t≤0.2s Non tripping Switch current by closing the auxiliary switch
    Cold 12In t< 0.2s Tripping Switch current by closing the auxiliary switch

    Specifications and technical parameters

    Model Pole Rated operating voltage(V) Rated current(A) Signal control trip action time(t)
    DZ47S-125 1P+N 230 63、80、100、125 0.5s≤t<3s
    3P+N 400 63、80、100、125

    Wiring: 35mm² and below for wire connection, select the wire cross-sectional area with reference to the following table when using it, terminals tightening torque is 3.5N · m.

    Rated current In(A) Copper conductor nominal cross-sectional area(mm²)
    63 16
    80 25
    100 35

    Overcurrent trip characteristic curve

    Application example:

    Structural characteristics and working principle

    Structure:

    The circuit breaker consists of DZ47-125 MCCB and signal-controlled release.
    DZ47-125 MCCB mainly consists of the insulated shell, operating system, contact system, thermal magnetic systems and arc extinction systems and other components. Signal control release consists of the signal input port, signal voltage detection circuit, delay control circuit and the trip mechanism and so on. MCCB and the signal control release have linkages by the pushrod.

    Circuit Breaker shunt trip features are as follows:
    The operating mechanism of the circuit breaker is a freewheel trip mechanism with energy storage. The contact is quickly closed, which overcomes the adverse effect caused by the speed of manual operation, greatly increases the service life of the shunt trip MCB. In normal operation, the contact can only stay in the closed or disconnected position. Case and parts are made of plastic of high flame-retardant, high temperature, impact-resistant. Signal-controlled release consists of the SCR, electromagnetic release components and so on. High breaking capacity, up to 6kA.
    Signal control Circuit Breaker shunt trip consists of the signal input port, signal processing systems and electromagnetic release components, to control remote signal through the external signal line.
    Products have small size, light weight, modular, unique appearance. It uses effective space layout rationally .
    Mounted on the standard rail, convenient and time-saving.

    Working principle:

    By the signal input port, the circuit breaker signal control release is added control voltage, witch is the signal voltage (which can be provided by the remote control circuit), and then push the breaker handle to the closed position, through the operating mechanism to make the moving contact operate to the static contact and contact with the static contact, then the line connected. When the line has overload fault, the overload current make bimetallic element bend, overload release action promotes the locking mechanism action to achieve breaking the line. When the line has short-circuit fault, the short-circuit current makes instantaneous release act, to promote the locking mechanism to achieve breaking function. When due to some need to immediately cut off the line, which can cut off control voltage by the remote control system, the signal voltage detects circuit and obtains the signal, then outputs the voltage signal to the trip coil to make the locking mechanism act and realize the breaking function. So the product in different line state can achieve the purpose of breaking.

    Outline and installation dimensions


    Keywords: shunt trip MCB,Circuit Breaker shunt trip

  • view and download

    File name(Click to view)File typefile sizeView timesClick to download

    Product related news

    News titlePromulgatorRelease timeView timesClick to read