    TXCM1 Molded Case Circuit Breaker (CM1-400, hereinafter referred to as MCCB), is new circuit breakers which have been designed and developed by the company using international advanced technology. The circuit breakers are of the following characteristics: compact size, high breaking capacity, short arc-over distance and shakeproof, is ideal products applied on land or ships. The rated insulation voltage of the circuit breaker is 800V (500V for TXCM1-63), it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage.
    TXCM1 MCCB can be mounted vertically (upright) or horizontally (transverse).
    TXCM1 MCCB is suitable for isolation and the symbol is " ".
    TXCM1 MCCB meets the standard: GB14048.2 "low-voltage switchgear and control equipment, Part 2: circuit breakers."

    Model and meaning

    Note:
    According to the pole, it classifies four types:
    Type A: N-pole without over-current release components, and N-pole has been connected all along, and does not act with other three poles to turn on or off;
    B-type: N-pole without over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);
    Type C: N-pole fixed with over-current release components, and N-pole could act with other three poles (N-pole turn-on prior to turn-off);
    D-type: N-pole fixed with over-current release components, and N-pole has been connected all along, and does not act with other three poles to turn on or off.
    Circuit breaker for distribution without code, circuit breaker for motor protection with 2
    No code for direct operation with handle; P for electric operation; Z for turning handle.
    Classification according to rated current of over-current release:
    TXCM1-63 MCCB has nine: 6,10,16,20,25,32,40,50,63 A;
    TXCM1-100 MCCB has nine: 16,20,25,32,40,50,63,80,100 A;
    TXCM1-225 MCCB has seven: 100,125,140,160,180,200,225 A;
    TXCM1-400 MCCB has five: 225,250,315,350,400 A;
    TXCM1-630 MCCB has three: 400,500,630 A;
    TXCM1-800 MCCB has three: 630,700,800A;
    TXCM1-1250 MCCB has three: 800,1000,1250A.
    Note: 6A only has electromagnetic (instantaneous) type, is not recommended specifications.
    According to the wiring method: wiring in front of board, wiring on back of board, insertion type of the board.
    According to over-current release pattern: thermodynamic-electromagnetic (double) type, electromagnetic (instantaneous) type.
    According to the outfit, it has two types: with or without outfit.
    The outfit include inner accessories and outside accessories: The inner accessories have shunt release, under-voltage release, auxiliary contact and alarm contact. The outside accessories are turning handle operation mechanism, power-driven operation mechanism and so on.
    According to the breaking capacity: L-standard breaking type; M-second high breaking type; H-high breaking type

    Normal operating conditions

    ■ Ambient air temperature: -5℃~+40℃, and average temperature in 24h is below +35℃.
    ■ Altitude: The altitude of the installation site is not more than 2000m.
    ■ Atmospheric conditions: The air relative humidity in the highest temperature +40℃ is not more than 50%; In the low temperature can have higher relative humidity. The maximum average relative humidity is 90%, while the average monthly minimum temperature is +25℃, and consider the temperature changes in product on the surface of the gel.
    ■ Pollution Degree: 3.

    四、Main technical parameters

    Trip mode and accessory code, flashover distance contains horizontal and vertical installation.

    Accessory name Accessory code Accessory installation and lead mode
    Instant
    aneous
    release
    Double
    release
    63A,100A 63A,100A,225A,400A 630A 800A 1250A
    2-poles 3-poles 4-poles 3-poles 4-poles 3-poles 3-poles
    Without accessory 200 300
    Alarm contact 208 308 ——
    Shunt release 210 310
    Pre-paid meter dedicated
    release
    210Y 310Y
    Auxiliary contact 220 320
    Undervoltage release 230 330
    Shunt release 240 340 ——
    Auxiliary contact 240Y 340Y
    Shunt release 250 350 —— —— —— ——
    Undervoltage release 250Y 350Y
    Two sets of auxiliary
    contacts
    260 360 ——
    Auxiliary contact,
    Undervoltage release
    270 370 ——
    Shunt release 218 318 —— —— —— ——
    Alarm contact 218Y 318Y
    Auxiliary contact,
    Alarm contact
    228 328 —— ——
    Undervoltage release,
    Alarm contact
    238 338 —— —— —— ——
    Shunt release,
    Auxiliary contact
    248 348 —— —— —— ——
    Alarm contact 248Y 348Y
    Shunt release,
    Undervoltage release, Alarm contact
    258 358 —— —— —— —— ——
    Two sets of auxiliary
    contacts, Alarm contact
    268 368 —— ——
    Auxiliary contact,
    Undervoltage release, Alarm contact
    278 378 —— —— —— ——

    A. 200 means circuit-breaker with electromagnetic release; 300 means thermodynamic+electromagnetic release; and 000 means circuit-breaker without release and internal accessory.
    B. 125, 250, 400, 2-pole products only have 210, 220, 230, 310, 320, 330.
    C. Only TXCM1-63, TXCM1-100, TXCM1-225, TXCM1-400 with pre-paid meter dedicated release.

    Main technical index

    1, Instantaneous action characteristic setting value of the circuit breaker for distribution is 10In±20%, TXCM1-1250 is 7In±20%; Instantaneous action characteristic set value of the circuit breaker for motor protection is 12In ± 20%.
    2, The rated value of the circuit breaker in Table 2.
    3, In the ambient temperature of +40℃, the circuit breaker for distribution over-current release action characteristics shown in Table 3, the circuit breaker for motor protection over-current release action characteristics shown in Table 4.


    Rated value of the circuit break

    Model Pole Rated current (A) Rated
    operating
    voltage (V)
    Rated
    insulation
    voltage (V)
    Rated ultimate short - circuit breaking capacity (Icu) Flashover
    distance(mm)
    Test voltage (V) Icu (kA) Ics (kA)
    TXCM1-63L 3 10、16、20、25、
    32、40、50、63
    400 500 400×1.10 25 18 0
    TXCM1-63M 3、4 50 35
    TXCM1-100L 3、4 16、20、25、32、40、
    50、63、80、100
    400 800 30 22 ≤50
    TXCM1-100M 2、3、4 50 35
    TXCM1-100H 3 85 50
    TXCM1-100L 3、4 690 10 5
    TXCM1-100M 2、3、4 20 10
    TXCM1-225L 3、4 100、125、140、
    160、180、200、225
    400 800 35 25
    TXCM1-225M 2、3、4 50 35
    TXCM1-225H 3 85 50
    TXCM1-225L 3、4 690 10 5
    TXCM1-225M 2、3、4 20 10
    TXCM1-400L 3 225、250、315、
    350、400
    400 800 50 35 ≤100
    TXCM1-400M 3、4 65 42
    TXCM1-400H 3 100 65
    TXCM1-400L 3 690 15 8
    TXCM1-400M 3、4 20 10
    TXCM1-630L 3 400、500、630 400 800 50 35
    TXCM1-630M 3、4 65 42
    TXCM1-630H 3 100 65
    TXCM1-630L 3 6910 15 8
    TXCM1-630M 3、4 20 10
    TXCM1-800M 3 630、700、800 400 800 75 50
    TXCM1-800H 3 100 65
    TXCM1-800M 3 4690 30 15
    TXCM1-1250 3 800、1000、1250 400 800 85 42
    TXCM1-1250 3 690 25 12.5

    Note: 2-poles, 4-poles circuit breakers, divided into L, M, H, they have the same breaking index as M-type.

    Characteristics of inverse time breaking action of circuit breakers over-current release for power distribution when every pole is power-on at the same time

    No. Test current I/In Set time Initial state
    1 Conventional non-tripping current 1.05 2h(In>63A),1h(In≤63A) Cold
    2 Conventional non-tripping current 1.30 2h(In>63A),1h(In≤63A) Immediately after Test 1

    Instantaneous action characteristic setting value of the circuit breaker for distribution is 10In±20%, and instantaneous action characteristic setting value of the circuit breaker for motor protection is 12In±20%.

    Characteristics of inverse time breaking action of circuit breakers over-current release for motor protection when every pole is power-on at the same time

    No. I/In Set time Initial state Remark
    1 1.0 >2h Cold  
    2 1.2 ≤2h Immediately after Test 1  
    3 1.5 ≤4min Cold 10≤n≤225
    ≤8min 225 < in ≤ 630
    4 7.2 4s≤T≤10s Cold 10≤In≤225
    6s≤T≤20s 225 < in ≤ 630

    Inverse time protection characteristic curve

    Derating factors table of temperature changes

    Model/Coefficient/Temperature +40℃ +45℃ +50℃ +55℃ +60℃
    TXCM1-63 1 0.94 0.88 0.80 0.72
    TXCM1-100 1 0.95 0.89 0.84 0.76
    TXCM1-225 1 0.96 0.91 0.87 0.82
    TXCM1-400 1 0.94 0.84 0.80 0.73
    TXCM1-630 1 0.93 0.88 0.83 0.76
    TXCM1-800 1 0.93 0.88 0.83 0.76
    TXCM1-1250 1 0.88 0.83 0.79 0.76

    Outline and installation dimensions

    Dimension of wiring in front of the board

    Dimension of wiring on back of the board

    Dimension of plug-in wiring

    Dimension of wiring in front of the board

    Model H H1 H2
    TXCM1-100L/2P 86 104 24
    TXCM1-100L/3P 68 86 24
    TXCM1-100M/3P 86 104 24
    TXCM1-100H/3P 86 104 24
    TXCM1-100M/4P 86 104 24
    TXCM1-100H/4P 86 104 24

    Dimension of wiring on back of the board

    Dimension of plug-in wiring

    Dimension of wiring in front of the board

    Model H H1 H2
    TXCM1-225L/2P 104 127 24
    TXCM1-225L/3P 86 110 24
    TXCM1-225M/3P 103 127 24
    TXCM1-225H/3P 103 127 24
    TXCM1-225M/4P 103 127 24
    TXCM1-225H/4P 103 127 24

    Dimension of wiring on back of the board

    Dimension of plug-in wiring

    Dimension of wiring in front of the board

    Model H H1 H2
    TXCM1-400L/3P - - -
    TXCM1-400M/3P - - -
    TXCM1-400H/3P - - -
    TXCM1-400L/4P - - -
    TXCM1-400M/4P - - -
    TXCM1-400H/4P - - -

    Dimension of wiring on back of the board

    Dimension of plug-in wiring

    Dimension of wiring in front of the board

    Model H H1 H2
    TXCM1-630M/3P - - -
    TXCM1-630H/3P - - -
    TXCM1-630M/4P - - -
    TXCM1-630H/4P - - -

    Dimension of wiring on back of the board

    Dimension of plug-in wiring

    Dimension of wiring in front of the board

    Model H H1 H2
    TXCM1-800H/3P - - -
    TXCM1-800H/4P - - -

    Dimension of wiring on back of the board

    Dimension of plug-in wiring

    Dimension of wiring in front of the board

    Accessories of circuit breakers

    1、Internal accessory of circuit breakers

    1.1 Shunt release
    Rated control supply voltage of the shunt release: AC50Hz, 230V, 400; DC110V, 220V, 24V; When between 70%~110%, can break the circuit breaker reliably.<

    When rated control supply voltage of the shunt release is DC24V, the maximum length of copper wire should meet the following requirements

    Rated control
    supply voltage Uc(DC24V)/Conductor area
    1.5mm² 2.5mm²
    100%Uc
    85%Uc
    150m
    100m
    250m
    160m

    If the requirements of the above table are not met, it is recommended to design the shunt release control circuit using the following figure

    1.2 Under-voltage release

    When the power supply voltage drops to under-voltage release rated voltage of 70% to 35% of the range, the under-voltage
    release circuit breaker reliable break; when the supply voltage is below the rated voltage undervoltage release 35% , Under-voltage
    release to prevent the circuit breaker is closed; when the supply voltage is higher than 85% of the rated voltage of the under-voltage
    release, the under-voltage release ensures that the circuit breaker is closed. The undervoltage releases are rated at AC50Hz, 230V,
    400V.
    Special Note: The circuit breaker with undervoltage release, only in the under-voltage with rated voltage, which can open and close
    normally.

    1.3 Pre-paid meter dedicated release

    The rated operating voltage Ue of the pre-paid meter dedicated release is AC230/50Hz, it can worknormally in the range of (65% ~ 110%) Ue. When the Ctrl is cut off, the circuit breaker will delay 0.5s ~ 2s to be opening.

    Wiring diagram of pre-paid meter dedicated release

    1.4 The rated value of auxiliary contacts and alarm contacts in Table 5

    Classification Conventional thermal current (Ith)

    Rated current when

    AC 400V Ie(AC-15)

    Rated current when

    DC 220V Ie(DC-13)

    Auxiliary contact 3 0.4 0.15
    Alarm contact 3 0.3 0.15

    a. Auxiliary contact

    b. Alarm contact
    Alarm contacts don't act when the circuit breaker opens and closes normally, alarm contacts switch between normal opening and normal closing only after free tripping or fault tripping.


    2、External Accessory for Circuit Breakers

    2.1 Motor operating mechanism. The rated value and code are shown in Table 6.

    Category/Model TXCM1-63. 125. 250 TXCM1-400. 630. 800. 1250
    Structure type Electromagnet Motor
    AC voltage code AC50Hz、230V、400 AC50Hz、230V、400
    DC voltage code DC110V、220V DC110V、220V

    NOTE: After the tripping of circuit-breaker with electric operating mechanism, the electric operating mechanism must make the circuit-breaker buckle again, then it can close.


    The principle diagram of the opening and closing of TXCM1-63、100、225 electric operating mechanism(AC)

    The principle diagram of the opening and closing of TXCM1-400、630、800、1250 electric operating mechanism(AC)


    2.2 Installation dimensions of manual operating mechanism shown in Table 10
    Diagram of handle mounting hole of TXCM1-63~800

    Total height of electric/manual operating mechanism of circuit breaker (mm)(shown in Table 12)

    Model Total height of electric
    operating mechanism H

    Installation dimensions

    of manual operating mechanism H

    TXCM1-63L 155 49
    TXCM1-63M/H 164 49
    TXCM1-100L 152 51
    TXCM1-100M/H 170 51
    TXCM1-225L 182 54
    TXCM1-225M/H 199 54
    TXCM1-400L/M/H 255 88
    TXCM1-630M/H 262 89
    TXCM1-800M/H 261 96
    TXCM1-1250H 290 103

    Quick Selection Table of TXCM1 Series Molded Case Circuit Breaker

    Corresponding
    letters
    Function name Function corresponding to the model
    a Model features

    TXCM1 Molded Case

    Circuit Breaker

    b Frame rated current code

    63A、100A、225A、

    400A、630A、800A、

    1250A

    c Breaking capacity characteristic
    code

    L-standard breaking type;

    M-second high breaking type;

    H-high breaking type

    d Operation mode code

    No code for handle operation;

    P for electric operation;

    Z for turning handle operation

    e Pole

    2-two poles;

    3-three poles;

    4-four poles

    f Release name

    2 Electromagnetic release;

    3 Double release

    g Accessory 00 Without accessory
    08 Alarm contact
    10 Shunt release
    20 Auxiliary contact
    30 Undervoltage release
    40 Shunt release, Auxiliary contact
    50 Shunt release, Undervoltage release
    60 Two sets of auxiliary contacts
    70 Auxiliary contact, Undervoltage release
    18 Shunt release, Alarm contact
    28 Auxiliary contact, Alarm contact
    38 Undervoltage release, Alarm contact
    48 Shunt release, Auxiliary contact, Alarm contact
    58 Shunt release, Undervoltage release, Alarm contact
    68 Two sets of auxiliary contacts, Alarm contact
    78 Auxiliary contact, Undervoltage release, Alarm contact
    10Y Pre-paid meter dedicated release
    40Y Pre-paid meter dedicated release, Auxiliary contact
    50Y Pre-paid meter dedicated release, Auxiliary contact, Undervoltage release
    18Y Pre-paid meter dedicated release, Alarm contact
    48Y Pre-paid meter dedicated release, Auxiliary contact, Alarm contact
    58Y Pre-paid meter dedicated release, Undervoltage release, Alarm contact
    h Application

    No code for distribution;

    2 for motor protection

    i Conventional products

    No code;

    T for transparent cover products

    j Amperage 10、16、20、25、32、63、80、100、125、160、180、200
    、225、250、315、350、400、500、630、700、800、1000
    、1250


    Example: TXCM1-100L / 33102 63A means TXCM1-type molded case circuit breaker, frame rated current is 100A, breaking capacity is the standard type, handle operation, 3 poles, double release, with shuntrelease, for motor protection, rated current is 63A.
    Selection, installation, use should be consistent with the product manual or the relevant national standards.
    Note: N-pole type of 4P circuit breaker is divided into A-type, B-type, which is not specified defaults to Btype.


    Keywords: CM1-400 , MCCB Circuit Breaker